Home ProductsTank calibration system

GUIHE factory price high accuracy short time easy operator tank volume table machine autoamtic tank calibration system

Good quality automatic tank gauge system for sales
Good quality automatic tank gauge system for sales
I'm Online Chat Now

GUIHE factory price high accuracy short time easy operator tank volume table machine autoamtic tank calibration system

China GUIHE factory price high accuracy short time easy operator tank volume table machine  autoamtic tank calibration system supplier
GUIHE factory price high accuracy short time easy operator tank volume table machine  autoamtic tank calibration system supplier GUIHE factory price high accuracy short time easy operator tank volume table machine  autoamtic tank calibration system supplier

Large Image :  GUIHE factory price high accuracy short time easy operator tank volume table machine autoamtic tank calibration system

Product Details:

Place of Origin: QINGDAO, CHINA
Brand Name: GUIHE
Certification: CE ,ISO
Model Number: GH-300

Payment & Shipping Terms:

Minimum Order Quantity: 1 set
Price: 1000-10000USD
Packaging Details: wooden case
Delivery Time: 10-15 days
Payment Terms: L/C, D/A, T/T, D/P, Western Union, MoneyGram
Supply Ability: 20 set /month
Contact Now
Detailed Product Description
Product Brand: GUIHE Or OEM Product Model: GH-300 Tank Calibration System
Usage: Automatic Tank Calibration System For Get The Tank Volume Table Liquid: To Suit All Liquid Material ,diesel ,gasoline ,petrol Light And Heavy Oil
Precision: High Precision Tank Calibration System Tank Calibration System: Tank Calibration System Machine

GUIHE factory price high accuracy short time easy operator tank volume table machine autoamtic tank calibration system

1. GH-300 autoamtic tank calibration system

 2. high accurcy GH-300 autoamtic tank calibration system

 3. picture 

GUIHE factory price high accuracy short time easy operator tank volume table machine  autoamtic tank calibration system

GUIHE factory price high accuracy short time easy operator tank volume table machine  autoamtic tank calibration system

Tank volume table calibration system

It’s necessary to calibrate the tank volume table

1,The nonstandard manufacturing, tilted installation of the tank will easy to cause the volume table inaccurate. This means a loss to the gas station.

Operational principle

2,This system consists of Tank Volume Table Calibration Instrument, Liquid Level Meter, Special Software and computer.

 

3, Fill the tank up, pump out the product to another tank or tanker though the Tank Volume Table Calibration Instrument, the product volume would be calculated automatically and the data would be uploaded to computer. Meanwhile, the data of product level collected by Liquid Level Meter uploaded to computer as well. According to the data uploaded, the Special Software will do analyze and process, and finally generate an accurate electronic volume table.

Characteristic

1,Need not manual operate whole processing, generate the volume table automatically.

2,This system can operate individually whether there is a computer.

3,It’s easy to use the software.

4,It’s convenient to move with compact design.

5,The fuel pump will never pump down as the system can setup a lowest product level limit.

6,The volume table is accurate as its error rate is 3‰~5‰

With fast operate speed , it’s less than 2.5 hours to measure a tank with 30m³

7,It features a protection function to avoid the data losing.

8,Users can import directly the volume table generated by this system into the Word or Excel.

Performance

Item GH-300 Tank Volume Table Calibration System
Purpose Tank Volume Table Calibration
Medium Gasoline, diesel, kerosene, ethanol etc.
State of medium Liquid
Explosion-proof grade DIIBT4
Pressure range -0.02Mpa~0.6 Mpa
Certificate PCEC Conformity Certificate of Explosion-proof / Permit of Manufacture Measuring Instruments
Temperature -40℃~70℃
Volume Accuracy 3‰~5‰
Product Level Accuracy ±0.2mm
Temperature Accuracy ±0.2℃
Height Resolution 0.01mm
Repeatability ±0.1mm
Environmental Temperature Effect Error<0.2mm
Vibration Effect Error<0.5mm
Lowest Product Inactive Zone 2.5'' floater-120mm
Measuring Range 10~30m³
Method of Communication RS-485
Measuring Time Less than 2.5 hours measuring one tank with 30m
Power Supply AC380V 50HZ
Protection Class of Case IP54

 

 

GUIHE factory price high accuracy short time easy operator tank volume table machine  autoamtic tank calibration system

Contact Details
QINGDAO GUIHE MEASUREMENT&CONTROL TECHNOLOGY.,LTD

Contact Person: Ms. ANNA

Tel: 86--13864261642

Fax: 86-532-88189858